<title><![CDATA[变频器在中央空调系统的节能应用]]></title>
<link>http://zhengfang.teamdo.com.cn/archives/2007/47511.html</link>
<description><![CDATA[<P><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>一、 水泵节能改造的必要性</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　中央空调是大厦里的耗电大户，每年的电费中空调耗电占<SPAN lang=EN-US>60%</SPAN>左右，因此中央空</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　调的节能改造显得尤为重要。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　由于设计时，中央空调系统必须按天气最热、负荷最大时设计，并且留<SPAN lang=EN-US>10-20%</SPAN>设计余量，然而实际上绝大部分时间空调是不会运行在满负荷状态下，存在较大的富余，所以节能的潜力就较大，其中，冷冻主机可以根据负载变化随之加载或减载，冷冻水泵和冷却水泵却不能随负载变化作出相应调节，存在很大的浪费。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　水泵系统的流量与压差是靠阀门和旁通调节来完成，因此，不可避免地存在较大截流损失和大流量、高压力、低温差的现象，不仅大量浪费电能，而且还造成中央空调最末端达不到合理效果的情况。为了解决这些问题需使水泵随着负载的变化调节水流量并关闭旁通。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　再因水泵采用的是<SPAN lang=EN-US>Y-△</SPAN>起动方式，电机的起动电流均为其额定电流的<SPAN lang=EN-US>3</SPAN>～<SPAN lang=EN-US>4</SPAN>倍，一台<SPAN lang=EN-US>90KW</SPAN>的电动机其起动电流将达到<SPAN lang=EN-US>500A</SPAN>，在如此大的电流冲击下，接触器、电机的使用寿命大大下降，同时，起动时的机械冲击和停泵时水垂现象，容易对机械散件、轴承、阀门、管道等造成破坏，从而增加维修工作量和备品、备件费用。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　综上，为了节约能源和费用，需对水泵系统进行改造，经市场调查与了解采用成熟的变频器来实现，以便达到节能和延长电机、接触器及机械散件、轴承、阀门、管道的使用寿命。 </FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　这是因为变频器能根据冷冻水泵和冷却水泵负载变化随之调整水泵电机的转速，在满足中央空调系统正常工作的情况下使冷冻水泵和冷却水泵作出相应调节，以达到节能目的。水泵电机转速下降，电机从电网吸收的电能就会大大减少。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　其减少的功耗<SPAN lang=EN-US> △P=P0</SPAN>〔<SPAN lang=EN-US>1-(N1/N0)3</SPAN>〕 （<SPAN lang=EN-US>1</SPAN>）式</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　减少的流量<SPAN lang=EN-US> △Q=Q0</SPAN>〔<SPAN lang=EN-US>1-(N1/N0)</SPAN>〕 （<SPAN lang=EN-US>2</SPAN>）式</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　 其中<SPAN lang=EN-US>N1</SPAN>为改变后的转速，<SPAN lang=EN-US>N0</SPAN>为电机原来的转速，<SPAN lang=EN-US>P0</SPAN>为原电机转速下的电机消耗功率，<SPAN lang=EN-US>Q0</SPAN>为原电机转速下所产生的水泵流量。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　 由上式可以看出流量的减少与转速减少的一次方成正比，但功耗的减少却与转速减少的三次方成正比。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　如：假设原流量为<SPAN lang=EN-US>100</SPAN>个单位，耗能也为<SPAN lang=EN-US>100</SPAN>个单位，如果转速降低<SPAN lang=EN-US>10</SPAN>个单位，由（<SPAN lang=EN-US>2</SPAN>）式<SPAN lang=EN-US>△Q=Q0</SPAN>〔<SPAN lang=EN-US>1-(N1/N0)</SPAN>〕<SPAN lang=EN-US>=100</SPAN>＊〔<SPAN lang=EN-US>1-(90/100)</SPAN>〕<SPAN lang=EN-US>=10</SPAN>可得出流量改变了<SPAN lang=EN-US>10</SPAN>个单位，但功耗由（<SPAN lang=EN-US>1</SPAN>）式<SPAN lang=EN-US>△P=P0[1-(N1/N0)3]=100</SPAN>＊〔<SPAN lang=EN-US>1-(90/100)3</SPAN>〕<SPAN lang=EN-US>=27.1</SPAN>可以得出，功率将减少<SPAN lang=EN-US>27.1</SPAN>个单位，即比原来减少<SPAN lang=EN-US>27.1%</SPAN>。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><FONT size=2><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA">　　再因变频器是软启动方式，采用变频器控制电机后，电机在起动时及运转过程中均无冲击电流，而冲击电流是影响接触器、电机使用寿命最主要、最直接的因素，同时采用变频器控制电机后还可避免水垂现象，因此可大大延长电机、接触器及机械散件、轴承、阀门、管道的使用寿命。</SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA">　　</SPAN></FONT><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　二、 水泵节能改造的方案</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　中央空调系统通常分为冷冻（媒）水和冷却水两个系统。根据国内外最新资料介绍，并多处通过对在中央空调水泵系统进行闭环控制改造的成功范例进行考察，现在水泵系统节能改造的方案大都采用变频器来实现。</FONT></SPAN></P>
<P><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA">1</SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA">、冷冻（媒）水泵系统的闭环控制</SPAN></FONT><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　　〔<SPAN lang=EN-US>1</SPAN>〕、制冷模式下冷冻水泵系统的闭环控制</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　该方案在保证最末端设备冷冻水流量供给的情况下，确定一个冷冻泵变频器工作的最小工作频率，将其设定为下限频率并锁定，变频冷冻水泵的频率调节是通过安装在冷冻水系统回水主管上的温度传感器检测冷冻水回水温度，再经由温度控制器设定的温度来控制变频器的频率增减，控制方式是：冷冻回水温度大于设定温度时频率无极上调。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　〔<SPAN lang=EN-US>2</SPAN>〕、制热模式下冷冻水泵系统的闭环控制</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　该模式是在中中央空调中热泵运行（即制热）时冷冻水泵系统的控制方案。同制冷模式控制方案一样，在保证最末端设备冷冻水流量供给的情况下，确定一个冷冻泵变频器工作的最小工作频率，将其设定为下限频率并锁定，变频冷冻水泵的频率调节是通过安装在冷冻水系统回水主管上的温度传感器检测冷冻水回水温度，再经由温度控制器设定的温度来控制变频器的频率增减。不同的是：冷冻回水温度小于设定温度时频率无极上调，当温度传感检测到的冷冻水回水温越高，变频器的输出频率越低。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　无锡伊莱克电气有限公司生产的系列智能变频器都具有以上功能，通过安装在冷冻水系统回水主管上的温度传感器（如图，安装在冷冻水系统回水主管上的<SPAN lang=EN-US>A</SPAN>处）来检测冷冻水的回水温度，并可直接通过设定变频器参数使系统温度调控在需要的范围内。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　另外，针对已往改造的方案中首次运行时温度交换不充分的缺陷，无锡伊莱克电气有限公司生产的系列智能变频器增加了首次起动全速运行功能，通过设定变频器参数可使冷冻水系统充分交换一段时间，然后再根据冷冻回水温度对频率进行无极调速，并且变频器输出频率是通过检测回水温度信号及温度设定值经ＰＩＤ运算而得出的。</FONT></SPAN></SPAN></P>
<P><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA">2</SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA">、冷却水系统的闭环控制</SPAN></FONT><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　目前，在冷却水系统进行改造的方案最为常见，节电效果也较为显著。该方案同样在保证冷却塔有一定的冷却水流出的情况下，通过控制变频器的输出频率来调节冷却水流量，当中中央空调冷却水出水温度低时，减少冷却水流量；当中中央空调冷却水出水温度高时，加大冷却水流量，从而达到在保证中中央空调机组正常工作的前提下达到节能增效的目的。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　现有的控制方式大都先确定一个冷却泵变频器工作的最小工作频率，将其设定为</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　下限频率并锁定，变频冷却水泵的频率是取冷却管进、出水温度差和出水温度信号来调节，当进、出水温差大于设定值时，频率无极上调，当进、出水温差小于设定值时，频率无极下调，同时当冷却水出水温度高于设定值时，频率优先无极上调，当冷却水出水温度低于设定值时，按温差变化来调节频率，进、出水温差越大，变频器的输出频率越高；进、出水温差越小，变频器的输出频率越低。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　无锡伊莱克电气有限公司通过市场调查与了解，并经多方实践应用与论证，现用于冷却水系统闭环控制的系列智能变频器采用同制冷模式下冷冻水泵系统闭环控制一样的控制方式。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　与其他厂家的控制方式相比，其优点有：</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　<SPAN lang=EN-US>1</SPAN>、 只需在中中央空调冷却管出水端安装一个温度传感器（如图，安装在冷却水系统中中央空调冷却水出水主管上的<SPAN lang=EN-US>B</SPAN>处），简单可靠。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　<SPAN lang=EN-US>2</SPAN>、 当冷却水出水温度高于温度上限设定值时，频率直接优先上调至上限频率。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　<SPAN lang=EN-US>3</SPAN>、 当冷却水出水温度低于温度下限设定值时，频率直接优先下调至下限频率。而采用冷却管进、出水温度差来调节很难达到这点。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　<SPAN lang=EN-US>4</SPAN>、 当冷却水出水温度介于温度下限设定值与温度上限设定值时，通过对冷却水出水温度及温度上、下限设定值进行ＰＩＤ计算，从而达到对频率进行无极调速，闭环控制迅速准确。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　<SPAN lang=EN-US>5</SPAN>、 节能效果更为明显。当冷却水出水温度低于温度上限设定值时，采用冷却管进、出水温度差来调节方式没有将出水温度低这一因素加入节能考虑范围，而仅仅由温度差来对频率进行无极调速，而采用上、下限温度来调节方式充分考虑这一因素，因而节能效果更为明显，通过对多家用户市场调查，平均节电率要提高<SPAN lang=EN-US>5</SPAN>％以上，节电率达到<SPAN lang=EN-US>20</SPAN>％～<SPAN lang=EN-US>40</SPAN>％。</FONT></SPAN><SPAN lang=EN-US style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><BR></SPAN><SPAN style="FONT-SIZE: 10.5pt; FONT-FAMILY: 宋体; mso-bidi-font-family: 宋体; mso-bidi-font-size: 12.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA"><FONT size=2>　　<SPAN lang=EN-US>6</SPAN>、 具有首次起动全速运行功能。通过设定变频器参数中的数值可使水系统充分交换一段时间，避免由于刚起动运行时热交换不充分而引起的系统水流量过小。</FONT></SPAN></SPAN></SPAN></P>
<P><BR>相关链接：<A href="http://www.chinaicmart.com/suppliers/306/2SC5474.html">2SC5474</A>　<A href="http://www.chinaicmart.com/suppliers/334/2SK2974.html">2SK2974</A>　<A href="http://www.chinaicmart.com/suppliers/314/2SD2604.html">2SD2604</A>　<A href="http://www.chinaicmart.com/suppliers/322/2SK1099.html">2SK1099</A>　<A href="http://www.chinaicmart.com/suppliers/311/2SD1760.html">2SD1760</A></P>
<P>各位商业朋友们，想知道够多的IC信息吗？请点击：<A href="http://www.dzsc.com/">http://www.dzsc.com/</A></P>]]></description>
<author>zhengfa333</author>
<pubDate>2007-10-18 14:03:00</pubDate>
</item>
<item>
<title><![CDATA[系统思考变频器的使用]]></title>
<link>http://zhengfang.teamdo.com.cn/archives/2007/47510.html</link>
<description><![CDATA[变频器业界的专家、学者、企业家、用户共聚一堂，历数我国变频器行业一年来取得的骄人成绩。虽然我国变频器市场仍旧是欧、美、日十大品牌占据主流，但我国变频器的十大品牌正在迅速的崛起，高水平的高压变频器已经能和国外的品牌匹敌，并且占有的市场分额逐年迅速增加。这是令变频器业界击鼓相庆可喜可贺的大事。但是我们也应当清醒的认识到，和欧美、日产品相比，我国变频器的产量、质量、品种和生产厂家的规模的差距还是不小，业界的同仁们应当利用我国正在大力提倡建设节约型社会、创新型国家的东风，缩小和欧美、日产品的差距。 
<P></P>
<P><I></I>　　随着变频器在各行各业的深入应用取得了令人瞩目成绩，也获得了显著节能效果、经济效益、环境效益和社会效益。在变频器这个专业模块范围内考虑的问题多，从变频节能系统整体层面上考虑的问题少，弄不清楚整个系统真实的特性是什么，也不怎么清楚变频器在整个系统的地位和作用，因而在一些项目中，变频器仅仅起到了掩饰水泵、风机容量选择过大的节能作用，而没有从理论上根本解决系统节能的实质问题，或者仅仅把变频器降格为一个挡风板的作用，花了很多投资上了变频器，而没有把变频器的作用发挥到极致。这不利于我国变频事业的健康发展。我觉得业界同仁们对于变频器的正确应用必须给以充分的重视，应用变频器产生极致的效益，是变频器发展的终极目的，也只有变频器应用正确、可靠、顺利，才能对广大用户产生更大的吸引力，变频器的市场才会有做大做强的巨大商机。我国每年节能服务市场的规模约有1200亿，外国巨头早就觊觎我国节能服务市场，他们已有大的举措，我们已经听到了这些巨人嗵嗵的脚步声，同仁们，形势紧张，机不可失，时不再来，让我们携起手来，为我国变频器事业蓬勃发展、为我国2020年达到全面的小康水平而努力奋斗！</P>
<P>2、变频器在系统中的作用</P>
<P><I></I>　　&nbsp;变频器在实际使用中是以一个子系统的角色容入大系统中进行协调运行的。如在图1的负反馈控制系统中，变频器和电机、风机或水泵一起作为控制系统的执行器，并和传感器、调节器及被控对象共同构成一个完整的控制系统整体。控制系统的性能取决于系统的结构，即控制系统的四个环节之间的相互联系、相互影响和相互制约也就是相互关联。各个环节局部都优组成的系统整体不一定最优，反之系统整体最优不一定要求每个环节局部最优。大部分变频器应用都可归结为这种运行模式。这就是说如果控制系统的四个环节不匹配，即便是变频器的性能再好，也显示不出来。</P>
<P>
<DIV align=center><IMG src="http://www.dzsc.com/data/uploadfile/20071099392533.jpg" border=0><BR>图1<I></I>&nbsp;变频器在控制系统中的作用</DIV><I></I>&nbsp;<I></I>&nbsp;<I></I>&nbsp;<I></I>&nbsp; 
<P></P>
<P><I></I>　　从图1可以看出，变频器构成的控制系统，跟踪的是与系统变化过程特点密切相关的特征参数θa，以克服干扰f造成的影响，而不是相关性很弱的其他参数。笔者在工程上曾见过这样的案例:在一个空调箱中，变频器不是跟踪反映负荷变化的特性参数，而是跟踪和负荷变化不相关的过滤器两侧的阻力降，变频器形同虚设，根本起不到跟踪负荷变化节能的作用。变频器和电动机、水泵组成的执行器环节的实质是变能量流，跟踪什么参数变，这是我们设计变频变流量节能系统应该特别要注意的。</P>
<P>3、变频器在火力发电厂应用节能案例剖析</P>
<P><I></I>　　图2是变频器在火电厂的应用方案图。在这个方案中只是突出了高压变频器（HVIN）、变压器P.T）和高压电机（M）组成的控制回路中的多半个环节，而没有说明高压变频器在控制系统中的位置和作用，因此有可能把高压变频器的功能发挥不到极致，取得最好的节能效果，或者使变频器降格为仅仅起到一个挡风板的作用，而没有发挥变频器应有的作用。</P>
<P>
<DIV align=center><IMG src="http://www.dzsc.com/data/uploadfile/20071099393867.jpg" border=0><BR>图2<I></I>&nbsp;变频器在火电厂的使用方案</DIV><I></I>&nbsp;<I></I>&nbsp;<I></I>&nbsp; 
<P></P>
<P><I></I>　　实际在电厂的风机、水泵处在的位置不同，用变频节能改造取得的节能效果也是不同的。</P>
<P><I></I>　　在火力发电厂中的风机、水泵配置的电动机基本上都是超过250kW的高压电动机，因此变频变流量节能应用都需要高压变频器。但生产流程中处在不同位置的风机或水泵，和高压变频器组成的控制系统跟踪的目标是不同的，节能的效果也是不同的。</P>
<P>
<DIV align=center><IMG alt="" src="http://www.dzsc.com/data/uploadfile/20071099393775.jpg" border=0><BR>图3<I></I>&nbsp;火力发电厂生产流程示意图</DIV>
<P></P>
<P><I></I>　　如图3中的循环水泵8。因冷却水受发电负荷、气候的影响，冷却水温会发生变化，从而影响冷凝器4的冷凝压力并波及汽轮机3的出力和效率，即影响发电机18的出力和效率，因此循环水泵8和高压变频器组成的控制系统应当跟踪的是冷凝器4的冷凝压力，以克服发电负荷、气候变化对发电效率的影响，保持发电机组在变工况的高效运行，同时由于控制系统能够根据发电出力和气候变化自动调节冷却水量，冷却泵8也以最小的能耗，实现了发电系统的高效运行，自身也得到了最大的节能效果。</P>
<P><I></I>　　又如，图3中的引风机17，分析它和变频器构成的控制系统跟踪的应是锅炉炉膛21的负压恒定，以保证在发电变负荷、大气压力随气候变化时变锅炉的高效燃烧，从而保持发电系统变工况时的高效运行。</P>
<P><I></I>　　再如，图3中的送风机15，分析它和变频器、蒸汽用量传感器、煤量传感器构成的复合控制系统跟踪的应是锅炉燃烧的风煤比，以保证在发电变负荷、大气压力随气候变化时锅炉的高效燃烧，从而保持发电系统的高效运行。</P>
<P><I></I>　　分析引风机17和送风机15的变频变流量控制系统都基本上是定压变流量系统，这是风机、水泵节能工程中最常用的模式。虽然从理论上可以证明定压变流量节能模式是不节能的，但如果它服从整个发电系统高效运行的整体目标，以最小的代价实现整个发电系统的高效运行，发电系统总体上仍是节能的，它为系统的整体节能目标做出了贡献，也就发挥了变频器的极致作用，取得了优良的节能效果。同时由于风机、水泵配置容量比实际的需求容量普遍偏大（至少大30%），变频器的使用也有掩盖这个缺点取得“遮丑”的节能效果。</P>
<P>4、变频器在油田注水采油应用节能案例剖析</P>
<P><I></I>　　在油田采油的后期，储油近于枯竭，为了提高油田的产能，普遍采用注水采油技术。</P>
<P><I></I>　　&nbsp;注水采油靠向含油层注入按比例加入阻垢剂、粘土稳定剂、缓蚀剂、化学驱油物质等化学原料处理过的混合水溶液，利用水淹含油层，在水的驱动下，石油和水一起被带出。图4为油田注水采油综合用能流程图。图4上的P2为高压注水泵，为了节能采用变频调速。</P>
<P>
<DIV align=center><IMG alt="" src="http://www.dzsc.com/data/uploadfile/20071099395764.jpg" border=0><BR>图4<I></I>&nbsp;油田注水采油综合用能流程图</DIV><I></I>&nbsp; 
<P></P>
<P><I></I>　　注水采油率:大庆（4.0m3水/吨原油），<I></I>&nbsp;靖边地方油田（17.4m3水/吨原油），每口注水井大概控制含油面积0.3～1.2k<I></I>&nbsp;m2、大约控制2口采油井，注水量30～50m3/d。由于含油层的地质构造千差万别，它的水渗透系数有很大的不同，同时随着采油的时间的变化，含油层的地质构造的水渗透系数也发生变化，因此从注水泵回路分析来看，相当于注水泵的负载阻力特性随含油层地质构造的不同和采油时间的变化而变化。对一个采油地区一段注水时间内，采单位重量原油的注水量基本恒定，所以这个系统跟踪的目标应当是水泵注水量恒定，才能保证注水采油的采油量。但随含油层的地质构造的水渗透系数的变化，对注水泵来说，工况点也要发生变化，为了保证注水泵在任何情况、任何频率下都在最高效率地运行，从系统思考的观点，应当在注水泵的出口增加一个阀门，作为调整注水泵工况点的补偿环节。要知道水泵回路阻力并不是越小消耗的动力越小，而是要回路阻力和水泵的特性相匹配，使水泵处在最高效率点工作，加上变频器控制系统跟踪注水流量恒定反馈控制，才能使变频节能的系统发挥到极致。</P>
<P><I></I>　　从图4也可以看出，给注水泵实现变频节能控制，只是注水采油节能系统中的一个环节，其他环保、节能的项目也应该一并考虑。如油水分离后的含油水，应当经过污水处理器处理后循环使用，否则含油污水乱排，很可能待油田寿终正寝后，留下的只是狼藉满地、一片污染的不毛之地。注水循环使用也可以减少地下清水的开采量，减轻地下含水层的采水量的负担。</P>
<P><I></I>　　又如，经过污水处理器处理过的中水，估计有30～40℃，每吨水含有23.3～34.9kWh可回收热量，供给加热热水或采暖供热，100m3/h的回水大概可以供给面积为2～3万m2住房、约200～300户家庭的采暖需求。如果把不经热回收的热水再注入地下，这部分热量就白白流失了。如果增加热泵热回收机组CH1，就可以达到热回收的目的。</P>
<P><I></I>　　从上面的分析可看出，变频器组成的控制系统，是以一个有机整体的面貌出现的，只有这个整体运行协调，并时刻服从更大系统的总体目标，变频器的功能才能发挥到极致，才能取得明显的节能效果。“系统是物质世界存在的基本形式和根本属性。”系统是一个活生生的统一的有机整体，而不是冷冰冰的机器堆积物。系统具有生物属性—有序、和谐、自然、均衡，有生命过程。我们应当遵从世界是按系统的模式运动的客观规律，应用“系统思考”的理念处理变频变流量节能的问题。只有牢牢树立符合客观规律的“系统思考”的意识，才能清楚地定位变频器在系统中正确的角色和作用，使变频器融入系统中并和“左邻右舍”共同构成有机的系统整体，变频器的功能才能发挥到极致，变频变流量系统才能取得最大的节能效果。我们遇到的变频变流量节能系统一般都是复杂的大系统，“系统思考”的理念是处理好当今复杂大系统工程惟一正确的、可行的正确理念。我想，随着时间的推移和用“系统思考”理念剖析变频器的实用案例的增多，“系统思考”理念是会很快被人们接受、熟悉，并在我国节能服务市场上大显威力的。</P>
<P>5、结束语</P>
<P><I></I>　　（1）<I></I>&nbsp;变频器的应用是融到系统当中的，变频器和电机、水泵共同组成控制系统的执行器这个环节。单从变频器专业模块考虑变频器的应用不利于变频业的健康发展。</P>
<P><I></I>　　（2）<I></I>&nbsp;变频器的节能效果，取决于变频器构成的整体系统的结构和性能，单在变频器这个专业模块范围内考虑问题，变频器不能发挥其极致功能。我们应当遵从客观规律，用“系统思考”的理念来推行变频器的应用。</P>
<P>&nbsp;</P>
<P>相关链接：<A href="http://www.chinaicmart.com/suppliers/336/2SK3337-01.html">2SK3337-01</A>　<A href="http://www.chinaicmart.com/suppliers/348/305UR250P3.html">305UR250P3</A>　<A href="http://www.chinaicmart.com/suppliers/300/2SC4399.html">2SC4399</A>　<A href="http://www.chinaicmart.com/suppliers/334/2sk3070.html">2sk3070</A>　<A href="http://www.chinaicmart.com/suppliers/321/2SJ602-S.html">2SJ602-S</A></P>]]></description>